B4800 - Hazardous Material Storage Building

B4800

Hazardous Material Storage Building Capacity - (48) 55 Gallon Storage Drums

Outside Dimensions: 8'6" X 26' X 8'"

Shipping Weight: 9963 lbs

Door Style: 1-60" W x 80" H door installed with a UL Classified commercial grade keyed lockset. The door shall serve as personnel entrance and exit.

Specifically designed for outdoor hazardous material storage and dispensing from 55-gallon drums containing flammable or combustible liquids. Outer wall is constructed of all-welded 16 or 12 gauge steel. Inner wall is constructed of 20 gauge steel. The double wall construction contains 3" of air space throughout. All Hazmat Storage Buildings are designed in accordance with the standards set forth by NFPA Code 30 and comply with OSHA and EPA regulations. All models are FM Approved for the storing and dispensing of flammable and combustible liquids. All electrical installations are U.L. Approved & Compliant to 1999 & 2002 NEC.

Add a Two Hour Fire Rating - OPFR2-4800

Add a Four Hour Fire Rating - OPFR4-4800

Add an Explosion Rating - OPXRP-4800

Approvals

Complies with EPA & current OSHA regulations

FM-Factory Mutual Approved

NFPA - Designed in accordance with specifications set forth by the National Fire Protection Association

UL - Include UL listed electrical accessories


Get Special Pricing

Quantity Discounts & More

Get Pricing
Product Details
Brand
Details
Specifications

Hazardous Material Storage Building Capacity - (48) 55 Gallon Storage Drums

Outside Dimensions: 8'6" X 26' X 8'"

Shipping Weight: 9963 lbs

Securall

Hazardous Material Storage Building Capacity - (48) 55 Gallon Storage Drums

Outside Dimensions: 8'6" X 26' X 8'"

Shipping Weight: 9963 lbs

Construction Features:

Exterior Walls: (Models B200 through B1200) 16 gauge galvannealed steel
Interior Walls: 20 gauge galvannealed steel (3" air space between walls)
Sump: 12 gauge steel liquid tight, continuously welded
Grating: Removable galvanized steel (Optional)
Forklift channel: 12 gauge galvanized steel
Grounding: OSHA Compliant Static Ground Connection inside and out on all explosion rated models
Labeling: NFR warning label, Hazard Rating System, Instructions
Venting: Natural convection vents
Explosion Relief Panels: 22 gauge steel opeing protected by expanded steel
Available with 2 or 4 hour fire rating
Chemical/corrosiv/ultraviolet resistant paint
Removable galvanized steel safety floor planking

Hurricane Resistant Wall

Securall Buildings have been tested to determine the amount of force they can withstand and were shown to withstand F-4 tornado force winds of 250 mph. The chart above demonstrates the wind speed that a particular length of wall will resist.

Upgrade package is available for Tornado Resistant Walls.

Exterior Wall Construction

Securall Hazamat Storage Buildings are all-welded using 12 gauge (B1600X-B8000X Models) and 16 gauge (B200X-B1200X Models) galvannealed steel outer walls and 20 gauge cold rolled steel inner walls provide maximum durability, weather resistance, and rigidity.

Fire Rating According to FM

Securall Fire-Rated Storage Buildings (8'4"H X 42'W X 9'D Max Dimensions) carry the Factory Mutual System Approval label and have an FM Approved Fire Rated Wall & Roof Design. Wall and Roof are Tested at Intertek Testing Laboratories. Securall Fire-Rated Storage Buildings constructed based upon UL Fire Resistance Ratings classification criteria. Standard models are available in 2-hour and 4-hour fire ratings. Wall ratings are either 2 or 4 hour fire rated . Roof ratings are either 1.5 or 3 hour fire rated (Check with your local authority having jurisdiction for correct wall/roof rating needed). In addition, all Fire-Rated Buildings come with hydraulic operated self-closing, fire-rated doors and fire damper protected vents.

Industry's 1st & Only Intertek Tested and FM Approved 2 Hour Fire Rated wall construction built with 1.5 hour fire rated roof construction, 1.5 hour fire rated door construction, and multiple layers of ¾” gypsum ultracode wallboard. Air inlet vents with UL Listed and labeled fire damper with louvers. Dampers have a galvanized steel frame, curtain-type galvanized steel blades and a UL Listed 165° F fusible link.

Industry's 1st & Only Intertek Tested and FM Approved 4 Hour Fire Rated wall construction built with 3 hour fire rated roof construction, 3 hour fire rated door construction, and multiple layers of ¾” gypsum ultracode wallboard. Air inlet vents with UL Listed and labeled fire damper with louvers. Dampers have a galvanized steel frame, curtain-type galvanized steel blades and a UL Listed 165° F fusible link.

Please check with your local authority having jurisdiction for setback requirements and correct wall/roof rating needed.

Safety Floor Planking

Slip resistant planking 13" wide, 12 gauge galvanized steel with raised perforated buttons and debossed holes protruding down. Galvanized steel floor planking above sump area for maximum corrosion resistance. Floor planking designed to sustain a minimum uniformly distributed load of 250 pounds per square foot. Floor planking and supports are removable to facilitate sump cleaning in the event of a spill.

Explsion Relief Panel

Used in the construction of buildings designed to store Class IA and Class IB flammables. Explosion relief panels limit the damage within an enclosed hazardous location. When the panel(s) are subjected to an explosive force, the pressure relieving panel quickly vents the force before it causes major damage. The panels are designed to release at 20 psf.

Factory Mutual System Approval

Securall Fire-Rated Hazardous Material Storage Buildings (10'H X 42'W X 9'D Max Dimensions) carry the Factory Mutual System Approval label and are constructed based upon UL Fire Resistance Ratings classification criteria. In addition, all Fire-Rated Buildings come with hydraulic operated self-closing, fire-rated doors and fire damper protected vents.

** Images may be shown with optional accessories **